Conduction Disorders And Their Clinical Impact After Sutureless/Rapid Deployment Aortic Bioprosthesis

Authors

  • Ricardo Ferreira Cardiothoracic Surgery Department, Santa Maria Hospital, Lisbon, Portugal https://orcid.org/0000-0003-0084-3916
  • Marta Figueiral Health sciences school, Universidade Beira Interior, Covilhã, Portugal
  • André Sena Cardiothoracic Surgery Department, Santa Maria Hospital, Lisbon, Portugal
  • Filipe Pereira Cardiothoracic Surgery Department, Santa Maria Hospital, Lisbon, Portugal
  • Nádia Junqueira Cardiothoracic Surgery Department, Santa Maria Hospital, Lisbon, Portugal
  • Tiago Velho Cardiothoracic Surgery Department, Santa Maria Hospital, Lisbon, Portugal
  • Ana Almeida Cardiothoracic Surgery Department, Santa Maria Hospital, Lisbon, Portugal
  • Angelo Nobre Cardiothoracic Surgery Department, Santa Maria Hospital, Lisbon, Portugal
  • Fausto Pinto Cardiology Department, Santa Maria Hospital, Lisbon, Portugal

DOI:

https://doi.org/10.48729/pjctvs.321

Keywords:

Aortic valve replacement, rapid deployment bioprostheses, pacemaker, complete atrioventricular block

Abstract

Introduction: Aortic stenosis remains the number one heart valve pathology. The drive to improve the surgical outcomes brought to focus rapid deployment valves (RDV), which reduce aortic cross-clamping and cardio-pulmonary bypass (CPB) times. However, some centers have reported a higher rate of conduction abnormalities and permanent pacemaker (PPM) implantation.

The aim of this study was to investigate the incidence of conduction abnormalities after aortic valve replacement with RDV, as well as its impact on immediate postoperative outcomes.

Methods: Retrospective analysis of associated conductions disorders and PPM implantation rates, as well as post-operative outcomes of all patients undergoing isolated aortic valve replacement between April 2014 and December 2019 with an RDV. Comparative analysis between the group with PPM implantation and the one with no PPM implantation. Patients with previous PPM implantation, reoperations and patients with missing pre or postoperative ECG data were excluded.

Results: We studied 201 patients. The majority of conduction abnormalities were left bundle branch block (54,0%). Twenty-six PPM were implanted (12,6%).

Pre-operative characteristic between the groups were similar and little differences were found in regard to most complications. However, the PPM group showed significantly higher rates of stroke (7.7% vs 0.0%, p=0.016) and hemodynamic support for longer than 24 hours (60.0% vs 36.1%, p=0.028). From the multivariable analysis, preoperative right bundle branch block was the only independent risk factor associated with PPM.

Conclusions: PPM implantation rates with RDV are relatively high and are associated with prolonged hospital and ICU stays, postoperative stroke rates and requirement of aminergic support. Their use should be made on a case-by-case basis taking into consideration the existence of preoperative conduction disorders, especially right bundle branch block.

Downloads

Download data is not yet available.

References

Thonghong T, De Backer O, Sondergaard L. Comprehensive update on the new indications for transcatheter aortic valve replacement in the latest 2017 European guidelines for the management of valvular heart disease. Open Heart. 2018;5(1):e000753.

Siemieniuk RA, Agoritsas T, Manja V, Devji T, Chang Y, Bala MM, et al. Transcatheter versus surgical aortic valve replacement in patients with severe aortic stenosis at low and intermediate risk: systematic review and meta-analysis. BMJ. 2016;354:i5130.

Tastet L, Tribouilloy C, Marechaux S, Vollema EM, Delgado V, Salaun E, et al. Staging Cardiac Damage in Patients With Asymptomatic Aortic Valve Stenosis. J Am Coll Cardiol. 2019;74(4):550-63.

Vahanian A et al. 2021 ESC/EACTS Guidelines for the manage- ment of valvular heart disase. Eur Heart J 2022; 43: 561-632.

Davidson LJ, Davidson CJ. Transcatheter Treatment of Valvular Heart Disease: A Review. JAMA. 2021 Jun 22;325(24):2480-2494. doi: 10.1001/jama.2021.2133. PMID: 34156404.

Berretta P, Di Eusanio M. Aortic valve replacement with su- tureless and rapid deployment aortic valve prostheses. J Geriatr Cardiol. 2016;13(6):504-10.

Laufer G, Wiedemann D, Chitwood WR, Jr. Rapid-deployment valves: Finally the fog is lifting-benefits beyond crossclamp and bypass times. J Thorac Cardiovasc Surg. 2017;154(5):1527-31.

Hanedan MO, Mataraci I, Yuruk MA, Ozer T, Sayar U, Arslan AK, et al. Early Outcomes of Sutureless Aortic Valves. Korean J Thorac Cardiovasc Surg. 2016;49(3):165-70.

Rahmanian PB, Kaya S, Eghbalzadeh K, Menghesha H, Mader- shahian N, Wahlers T. Rapid Deployment Aortic Valve Replacement: Excellent Results and Increased Effective Orifice Areas. Ann Thorac Surg. 2018;105(1):24-30.

Herry M, Laghlam D, Touboul O, Nguyen LS, Estagnasie P, Brusset A, et al. Pacemaker implantation after aortic valve replacement: rapid-deployment Intuity(R) compared to conventional bioprostheses. Eur J Cardiothorac Surg. 2020.

Gonzalez Barbeito M, Estevez-Cid F, Pardo Martinez P, Velasco Garcia de Sierra C, Iglesias Gil C, Quinones Laguillo C, et al. Surgical technique modifies the postoperative atrioventricular block rate in sutureless prostheses. J Thorac Dis. 2019;11(7):2945-54.

Ferreira, R, Rua, N, Sena, A, et al. Sutureless bioprosthesis for aortic valve replacement: surgical and clinical outcomes. J Card Surg. 2022; 37: 4774-4782.

Nardi P, Pellegrino A, Scafuri A, Bellos K, De Propris S, Polisca P, et al. Permanent pacemaker implantation after isolated aortic valve replacement: incidence, risk factors and surgical technical aspects. J Cardiovasc Med (Hagerstown). 2010;11(1):14-9.

Rück A, Saleh N, Glaser N, et al. Outcomes Following Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement. J Am Coll Cardiol Intv. 2021 Oct, 14 (19) 2173–2181.

Richard S. Gordon B, Joan Ivanov, MSc, Gideon Cohen, MD, and Anthony L. Ralph-Edwards, MD. Permanent Cardiac Pacing After a Cardiac Operation: Predicting the Use of Permanent Pacemakers. Annals of Thoracic Surgery. Vol 66, Issue 5, November 1998, Pages 1698-1704

Fujita B, Schmidt T, Bleiziffer S, Bauer T, Beckmann A, Bekeredjian R, et al. Impact of new pacemaker implantation following surgical and transcatheter aortic valve replacement on 1-year outcome. Eur J Cardiothorac Surg. 2020;57(1):151-9.

Ensminger S, Fujita B, Bauer T, Mollmann H, Beckmann A, Bekeredjian R, et al. Rapid Deployment Versus Conventional Bioprosthetic Valve Replacement for Aortic Stenosis. J Am Coll Cardiol. 2018;71(13):1417-28.

Puga BMV, Gallardo MY. Importance of atrioventricular synchrony for cardiac output in a patient with heart failure and reduced ejection fraction. CorSalud. 2019;11(1):75-78.

Yanagawa B, Verma S, Mazer CD. Subclinical Valve Thrombosis in Sutureless Bioprosthetic Valves. J Am Heart Assoc. 2017;6(8):e006862. Published 2017 Aug 21. doi:10.1161/ JAHA.117.006862

Vogt F, Moscarelli M, Nicoletti A, Gregorini R, Pollari F, Kalisnik JM, et al. Sutureless Aortic Valve and Pacemaker Rate: From Surgical Tricks to Clinical Outcomes. Ann Thorac Surg. 2019;108(1):99-105.

Iqbal AM, Jamal SF. Pacemaker Syndrome. [Updated 2022 Aug 29]. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2022 Jan-. Available from: https://www.ncbi.nlm.nih. gov/books/NBK536976/?report=classic

Vogt F, Pfeiffer S, Dell'Aquila AM, Fischlein T, Santarpino G. Sutureless aortic valve replacement with Perceval bioprosthesis: are there predicting factors for postoperative pacemaker implantation? Interact Cardiovasc Thorac Surg. 2016;22(3):253-8.

Baert J, Astarci P, Noirhomme P, de Kerchove L. The risk of oversizing with sutureless bioprosthesis in small aortic annulus. J Thorac Cardiovasc Surg. 2017;153(2):270-2.

Downloads

Published

04-04-2023

How to Cite

1.
Ferreira R, Figueiral M, Sena A, Pereira F, Junqueira N, Velho T, Almeida A, Nobre A, Pinto F. Conduction Disorders And Their Clinical Impact After Sutureless/Rapid Deployment Aortic Bioprosthesis. Rev Port Cir Cardiotorac Vasc [Internet]. 2023 Apr. 4 [cited 2024 Apr. 19];30(1):23-30. Available from: https://pjctvs.com/index.php/journal/article/view/321

Issue

Section

Original Articles

Categories

Most read articles by the same author(s)

<< < 1 2