Temporary Right Ventricular Assist Device After Redo Aortic Valve Replacement And Heartmate 3tm Implantation – A Case Report
DOI:
https://doi.org/10.48729/pjctvs.240Keywords:
Heart failure, HeartMate 3, Centrimag system, long-term mechanical circulatory support, temporary right ventricular assistance deviceAbstract
The implantation of the left ventricular assist device Abbott HeartMate 3TM is being increasingly performed for management of end-stage heart failure. LVAD implantation might be associated with early or late right ventricular dysfunction. When severe, a temporary right ventricular support device may need to be implanted. However, these situations are associated with higher mortality. We report a successful case of temporary right ventricular support following HeartMate 3 implantation.
Downloads
References
Mendes V, Cerca C, Crosset M, Kirsh M. Two Years of Experience in the Implantation of Heartmate III. Rev Port Cir Car- diotorac Vasc. 2017 Jul-Dec;24(3-4):120. PMID: 29701352.
Nowacka A, Hullin R, Tozzi P, Barras N, Regamey J, Yerly P, Rosner L, Marcucci C, Rusca M, Liaudet L, Kirsch M. Short- term single-centre experience with the HeartMate 3 left ventricular assist device for advanced heart failure. Eur J Cardiothorac Surg. 2020 Sep 1;58(3):511-518. doi: 10.1093/ejcts/ezaa075. PMID: 32236472.
Kormos RL, Teuteberg JJ, Pagani FD, Russell SD, John R, Miller LW, Massey T, Milano CA, Moazami N, Sundare- swaran KS, Farrar DJ; HeartMate II Clinical Investigators. Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes. J Thorac Cardiovasc Surg. 2010 May;139(5):1316-24. doi: 10.1016/j.jtcvs.2009.11.020. Epub 2010 Feb 4. PMID: 20132950.
Argiriou M, Kolokotron SM, Sakellaridis T, Argiriou O, Charitos C, Zarogoulidis P, Katsikogiannis N, Kougioumtzi I, Machairiotis N, Tsiouda T, Tsakiridis K, Zarogoulidis K. Right heart failure post left ventricular assist device implanta- tion. J Thorac Dis. 2014 Mar;6 Suppl 1(Suppl 1):S52-9. doi: 10.3978/j.issn.2072-1439.2013.10.26. PMID: 24672699; PMCID: PMC3966152.
Bhama JK, Kormos RL, Toyoda Y, Teuteberg JJ, McCurry KR, Siegenthaler MP. Clinical experience using the Levitronix CentriMag system for temporary right ventricular mechanical circulatory support. J Heart Lung Transplant. 2009 Sep;28(9):971-6. doi: 10.1016/j.healun.2009.04.015. PMID: 19716053.
Niclauss L, Roumy A, Kirsch M. Semi-Percutaneous ShortTerm Support of Right Heart Failure in Acute Aortic Dissection. Science Repository. 2021 Apr. doi:10.31487/j. SCR.2021.04.07
Lenoir M, Quessard A, N'guyen A, Kirsch M. Simplified temporary right ventricular support after implantation of a left ventricular assist device. Heart Surg Forum. 2013 Jun;16(3):E152-4. doi: 10.1532/HSF98.20131003. PMID: 23803240.
Reid G, Mork C, Gahl B, Appenzeller-Herzog C, von Segesser LK, Eckstein F, Berdajs DA. Outcome of right ventricular assist device implantation following left ventricular assist device implantation: Systematic review and meta-analysis. Perfusion. 2021 Jun 11:2676591211024817. doi: 10.1177/02676591211024817. Epub ahead of print. PMID: 34112048.
Griffith KE, Jenkins E, Stulak J, Paugh T, Pagani FD. Long-term use of the CentriMag® Ventricular Assist System as a right ventricular assist device: a case report. Perfusion. 2012 Jan;27(1):65-70. doi: 10.1177/0267659111424634. Epub 2011 Oct 24. PMID: 22025358.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Portuguese Journal of Cardiac Thoracic and Vascular Surgery
This work is licensed under a Creative Commons Attribution 4.0 International License.